Filter Results By:

Products

Applications

Manufacturers

Showing results: 1141 - 1155 of 1675 items found.

  • Environmental Chambers

    Iwasaki Electric Co., Ltd.

    Whatever your application, from an environmental chamber for small components to an extensive array for a complete automobile or aircraft test, EYE / Iwasaki has the experience to provide a solar lighting system customized for your requirements. Our systems are designed to be flexible and deliver the optimum solar simulation solution. We do not force-fit a "standard" system to attempt to meet your needs.

  • Bustec VISA Library And Tools

    ProDAQ 8200 - Bustec Ltd.

    The Virtual Instrument Software Architecture (VISA) is a standard for configuring, programming, and debugging data acquisition and test systems using hardware interfaces like Ethernet, USB, PCI Express, GPIB, IEEE1394 or even RS232. The VISA library provides a standardized application programming interface between the hardware and application programming environments like LabVIEW, LabWindows, Visual Basic etc.

  • SSD Test Systems

    MPT3000ES / MPT3000ES2 - Advantest Corp.

    Using the same high-performance electronics and powerful software as all products in the MPT3000 family, the MPT3000ES and MPT3000ES2 engineering stations feature a small footprint configured to test up to eight SSDs in parallel. The system's small size and ability to plug into a standard AC outlet enable users to conduct program development and interactive device debugging in either office or lab settings.

  • Two-Way Optical Loss Tester

    KI23403OLV-INGAAS-APC-50U - Kingfisher International

    A Two-Way Optical Loss Tester (OLTS) that's perfect for medium to ultra high fiber count loss, length and optical return loss testing applications on multimode fiber at 850 / 1330nm. A pair of these compact instruments set new standards of productivity, accuracy and ease of use. A multimode APC connector on this model is required for reliable ORL test performance.

  • New Battery Resistance Tester

    Hangzhou Xun Anda Electrical Co., Ltd.

    maximum capacity of the battery:200AH/2000CCA(SAE)Voltage test range: 1.5-15VDCWorking voltage 1.5-15VDC,powered by the tested batterMaxim Power Consumption: around 0.5WOperating temperature: -10°C~50°C Operating humidity: 30%~90%, without condensationdisplay modes: Four different colors LED indicatorbutton: 3 buttons.Test Standard: SAE,DIN,EN,IEC,CA.

  • Temp Characterized CalPod, 20 GHz

    85531B - Keysight Technologies

    CalPods provide a new and unique way to quickly and easily refresh a network analyzer calibration, at the push of a button and without removing the DUT or re-connecting standards. Very useful in thermal chamber testing, where it is desired to remove the thermal effects of the test cables and connectors from the DUT’s response, and where it is impractical to stop the thermal testing to perform a normal re-calibration.

  • TEST BOX

    6280 TB - Standard Electric Works Co., Ltd

    ● Wide range of operating voltage from AC 210V/50Hz to 250V/50Hz.● For checking AC voltage.● For checking a RCD tester's test current & time in mA(ms).● For checking a loop tester.● For wiring check (Phase, Neutral, Earth).● For checking continuity.● For checking insulation (The maximum is 1.2kV).● For checking UK16th edition.● Safety standard: EN 61010-1 / EN 61326-1

  • USB Modular Source Measure Unit

    U2722A - Keysight Technologies

    The U2722A USB Modular Source Measure Unit is a 3-channel 20V/120mA that can operate in a 4-quadrant operation. The channels could be connected in series or in parallel to achieve up to 60 V/360 mA. It uses the common non-proprietary standard high-speed USB 2.0 interface that provides ease of connectivity allowing users to set up and configure their tests swiftly with its plug and play feature.

  • Dielectric Breakdown Voltage and Dielectric Strength

    ASTM D149 - National Technical Systems

    This test method covers procedures for the determination of dielectric strength of solid insulating materials at commercial power frequencies, under specified conditions. Unless otherwise specified, the tests shall be made at 60 Hz. However, this test method is suitable for use at any frequency from 25 to 800 Hz. At frequencies above 800 Hz, dielectric heating is a potential problem. This test method is intended to be used in conjunction with any ASTM standard or other document that refers to this test method. References to this document need to specify the particular options to be used. It is suitable for use at various temperatures, and in any suitable gaseous or liquid surrounding medium. This test method is not intended for measuring the dielectric strength of materials that are fluid under the conditions of test. This test method is not intended for use in determining intrinsic dielectric strength, direct-voltage dielectric strength, or thermal failure under electrical stress (see Test Method ASTM D3151). This test method is most commonly used to determine the dielectric breakdown voltage through the thickness of a test specimen (puncture). It is also suitable for use to determine dielectric breakdown voltage along the interface between a solid specimen and a gaseous or liquid surrounding medium (flashover). This test method is similar to IEC Publication 243-1. All procedures in this method are included in IEC 243-1. Differences between this method and IEC 243-1 are largely editorial. Note: The above information is taken directly from the test method Scope published in ASTM D149.

  • Electrical Safety Test Equipment

    IBEKO Power AB

    Making a product “safe” requires an understanding of “hazards” that exist in each electrical product. Electrical shock is one of the four fundamental hazards. Because of that, it must be a part of any product electrical safety evaluation. Even though a product requires an electrical power source and uses electrical or electronic components, it should not present an electrical shock hazard to the user.Ground bond or earth continuity testing prevents electrical shock hazards. Similarly to a fault to earth, test instruments generate a high current. The standard requires that the resistance between protective earth and any conductive surface on the equipment does not exceed 0,1 Ohm. The test is performed by applying a DC current between the conductive surface and protective earth. By measuring the voltage drop, it calculates the resistance.RMO-E instruments are ideal for testing the protective bonding (grounding) of equipment following the standard IEC 61010-1. Applying current up to the value of 100 A and the ability to provide in the Contin menu (continuous operation) test current for the pre-set test duration (equal or exceeding 1 min) gives a user a possibility to easily check the protective bonding/grounding of the equipment. The full load voltage of 12 V assures proper measurement and accurate result. Finally, an instrument displays pass/fail classification according to user-preset parameters.

  • Gas Chromatography

    Shimadzu Corp.

    A gas chromatograph (GC) is an analytical instrument that measures the content of various components in a sample. The analysis performed by a gas chromatograph is called gas chromatography.Principle of gas chromatography: The sample solution injected into the instrument enters a gas stream which transports the sample into a separation tube known as the "column." (Helium or nitrogen is used as the so-called carrier gas.) The various components are separated inside the column. The detector measures the quantity of the components that exit the column. To measure a sample with an unknown concentration, a standard sample with known concentration is injected into the instrument. The standard sample peak retention time (appearance time) and area are compared to the test sample to calculate the concentration.

  • SSG Series Strain Gauge Extensometers

    Shimadzu Corp.

    Shimadzu’s SSG series of strain gauge extensometers are compliant with ISO, JIS, and ASTM tensile test standards, including those for plastics and metallic materials These lightweight, precision extensometers feature a wide elongation measurement range, while retaining the flexibility to measure using small gauge lengths, and support both rod and flat plate shaped specimens. Consisting of an elongation sensor and amplifier, this extensometer is suitable for use with metals and hard plastic materials, and is fastened securely to specimens with screws. Calibration using an extensometer calibrator allows the extensometer to meet JIS and ISO Class 0.5 and ASTM Class C standards for higher accuracy.

  • Leeb Hardness Testers

    GAO Tek Inc.

    GAOTek proudly presents an extensive and wide range of Leeb hardness testers for sale to the United States, Canada and globally. A Leeb hardness tester is used mainly in the manufacturing industry to test the structural integrity of a metal object by applying a definite amount of force on the object. Structural integrity is crucial information as in some cases it is treated as a specification or standard that companies must meet in order to release a product. It may also be used to set a limitation or restriction for a specific device or item. Our testers are designed to ensure standards are met by providing users with a variety of features to make the process of testing and monitoring results efficient and convenient.

  • Portable Meter Test Kit

    UTEC 430 - Radian Research, Inc.

    The UTEC 430 is the first Portable Meter Test Kit to support both the Radian Dytronic (RD) and the installed base of Radian Metronic (RM) reference standards. The ability to support both reference standards makes the 430 the ideal budgetary solution for traditional on-site meter testing using Phantom Load current sourcing. Do not let its compactness fool you, the UTEC 430 has three 30 Amp current output elements for performing single-phase or three-phase meter testing. When each element is combined using the optional open link cable harness, the UTEC 430 can source up to 90 Amps.

  • Complete Field Meter Site Testing Solution

    7 Series - Powermetrix Systems

    We raised the industry standard by introducing the PowerMaster 7 Series as a true 3-phase analyzing reference standard with internal 3-phase current and voltage source capability. The innovative design of the PowerMaster® 7 Series allows utilities to fully test a metering installation with one piece of equipment. Customer load meter testing, phantom load meter testing, CT burden and ratio testing, CT de-magnetization, PT ratio testing, and transducer testing can all be performed with one solution. In addition, vector diagrams, voltage and current waveforms, and harmonics data up to the 100th harmonic can all be analyzed to complete a true wiring verification.

Get Help